1.Drop

Drag and drop question. Drag the items to the proper

locations.
Correct Answers:    642-456 220-602 642-892

2.Drop

Drag and drop question. Drag the items to the proper

locations.
Correct Answers:

3.Given the following options, what is the correct

solution for a customer with the requirement to mirror

between two data centers that are nearly 200 km apart?

A: CWDM
B: DWDM
C: Native Fiber Channel
D: iSCSI
Correct Answers:  B

4.A customer would like to deploy a low-cost solution

to implement an asynchronous database-replication

application across a distance of 100 kilometers. Select

the lowest-cost solution that will meet the

requirements.

A: CWDM
B: DWDM
C: FCIP
D: SONET/SDH
Correct Answers:  C

5.Which two are optimal topologies for deployment of

Fibre Channel SANs using Cisco MDS family products?

(Choose two.)

A:mesh
B:ring
C:core-edge
D:collapsed core
E:core-edge with VSAN
Correct Answers:  D, E   642-873 640-822 350-018 70-432

6.A customer wants to consolidate the storage in an

existing SAN where Cisco MDS Series Switches are

deployed. How can the customer accomplish this goal and

still be able to retain full access to the data?

A: dual supervisor modules
B: virtual output queuing (VOQ)
C: stateful failover
D: universal interoperability mode 4
E: per-VSAN FSPF routing
Correct Answers:  E

7.Refer to the exhibit. Given the core topology and

switch build-out, which percentage of ports is

available for end devices?

A: 70 percent
B: 85 percent
C: 92 percent
D: 95 percent
Correct Answers:  C

8.What technology minimizes the potential for service

interruption on SAN extension links?

A: FCIP
B: VRRP
C: VSANs and IVR
D: Port Channeling
Correct Answers:  D   70-294 642-691 642-383

9.A customer is deploying a number of Cisco MDS 9509

Multilayer Directors in a new data center. At the time

of installation, it was discovered that the high-

voltage circuits (220 VAC) had not been installed but

the standard power circuits (110 VAC) had been

installed. The customer decided to install one of the

directors and use the 110-VAC circuit. The MDS 9509 is

configured with two 2500-W AC power supplies. The power

supplies are configured in redundant mode.

What is the redundant power capacity of the MDS 9509 in

this scenario?

A: 1000 W
B: 1300 W
C: 2000 W
D: 2500 W
E: 2600 W
Correct Answers:  B

10.Which three applications would be best suited for a

SAN rather than a NAS environment? (Choose three.)

A:web content services
B:order entry and inventory tracking
C:enterprise resource planning (ERP)
D:office productivity suites (for example, Microsoft

Office)
E:credit card transactions
F:engineering collaboration (for example, CAD and CAM)
Correct Answers:  B, C, E